8–10 mins Rapid Readout Time | 500 µg/kg Regulatory LOD (0.5 ppm) | 20 Tests Extended Kit Pack | 18 Months Shelf Life (4–30°C) |
The FSTest Auramine O Rapid Test Kit (Basic Yellow 2) is a competitive inhibition lateral flow immunochromatographic assay engineered for rapid qualitative screening of illegal Auramine O dye residues in durian.
Auramine O is a toxic industrial diarylmethane dye strictly prohibited in food due to its carcinogenic and mutagenic risks. Offering an on-site detection threshold of 500 µg/kg (0.5 mg/kg) with clear visual results in only 8 to 10 minutes, this test kit allows fresh fruit importers, wholesalers, customs quarantine agencies, and food safety labs to conduct fast, dependable screening without relying on complex analytical instruments.
Tailored Matrix Optimization: Specifically engineered and validated for challenging fruit matrices (durian pulp and peel), effectively eliminating natural matrix color and texture interference.
High Regulatory Sensitivity (500 µg/kg LOD): Accurately captures illegal Auramine O dye at 500 µg/kg (0.5 ppm), fully satisfying food safety surveillance standards.
Fast Visual Readout in 8–10 Minutes: Enables rapid qualitative interpretation on-site, drastically speeding up port-of-entry quarantine inspections and wholesale dispatch.
Simplified Sample Preparation: Requires no organic solvent extraction or complex SPE clean-up steps; utilizes a safe, ready-to-use aqueous dilution buffer.
Ambient Storage & Extended Shelf Life: Sealed storage at 4–30°C in a dry place with an 18-month shelf life, eliminating cold-chain transport dependency.
| Product Name | Auramine O Rapid Test Kit (Colloidal Gold) |
|---|---|
| Catalog Number | 24134 |
| Target Analyte Compound | Auramine O (Basic Yellow 2 | CAS: 2465-27-2 | C₁₇H₂₂ClN₃ | 303.83 g/mol) |
| Detection Principle | Competitive Lateral Flow Immunochromatography (Colloidal Gold) |
| Pack Size | 20 tests / kit |
| Assay Run Time & Volume | 8–10 minutes (results invalid after 10 minutes); 100 µL test supernatant |
| Storage & Shelf Life | 18 months sealed at 4–30°C in a cool, dry place (Do not freeze) |
| Target Analyte Compound | CAS Registry Number | Molecular Formula | Limit of Detection (LOD) |
|---|---|---|---|
| Auramine O (Basic Yellow 2) | 2465-27-2 | C₁₇H₂₂ClN₃ | 500 µg/kg (0.5 mg/kg) |
Specifically engineered for identifying illegal dyeing practices in tropical fruit commodities:
STEP 1 Extraction Homogenize representative sample (> 100 g). Weigh 2.0 ± 0.1 g into a 15 mL tube, add 3 mL Dilution Solution, and vortex vigorously for 2 minutes. | STEP 2 Centrifugation Centrifuge the tube at 4000 rpm for 5 minutes. The clear supernatant serves as ready-to-test solution (avoid aspirating floating debris). | STEP 3 Microwell Incubation Ensure 20–40°C environment. Pipette 100 µL supernatant into a microwell, mix up and down 3–5 times, and incubate undisturbed for 3 minutes. | STEP 4 Load & Read (8–10 Mins) Transfer all mixed liquid from microwell into cassette sample well. Interpret visual lines strictly at 8–10 minutes. Results are invalid after 10 minutes. |
Negative (-): Both Test (T) line and Control (C) line appear clearly. T line color intensity is equal to or darker than C line → Auramine O is absent or below 500 µg/kg.
Positive (+): Control (C) line appears distinctly, while Test (T) line is invisible or visibly lighter than C line → Auramine O is present at or above 500 µg/kg.
Invalid: Control (C) line fails to appear, regardless of whether T line is visible. Re-test with a fresh cassette.
Adhere to strict operational parameters to ensure maximum screening accuracy:
Qualitative Nature: Engineered strictly for preliminary qualitative screening; positive samples should be confirmed using chromatography methods (HPLC / LC-MS).
Moisture Protection: Start testing within 1 hour after removing the cassette from the foil pouch to prevent atmospheric moisture absorption and strip failure.
Environmental Conditions: Maintain operating ambient temperature between 5–40°C and relative humidity between 30%–80%. Perform assays sheltered from direct wind.
Strict Time Window: Read visual test results strictly between 8–10 minutes after loading cassette; results observed after 10 minutes are invalid.
Kit Components Included: 20 Test Cassettes (individually sealed with desiccant), 20 Microwells (pre-coated reagent wells), 20 Centrifuge Tubes (15 mL), 1 bottle of Dilution Solution (70 mL), User Manual.
Required Equipment (Not Provided): Sample homogenizer/blender, analytical balance (0.1 g precision), vortex mixer, centrifuge (≥ 4000 rpm), micropipette (100 µL range) & tips, and timer.