5–8 mins Visual Readout Window | 1000 µg/kg Regulatory MRL Limit | 10 Tests Direct-Load Kit Pack | 18 Months Shelf Life (4–30°C) |
The FSTest Vomitoxin (DON) Rapid Test Kit is a competitive lateral flow immunochromatographic assay engineered for the rapid qualitative screening of Vomitoxin (Deoxynivalenol, DON) mycotoxin residues in cereal grains and legumes.
Vomitoxin (DON) is a prevalent trichothecene mycotoxin produced by Fusarium species in wheat, corn, barley, and oats, causing acute gastrointestinal distress, immunosuppression, and feed refusal in livestock. Calibrated precisely to the standard regulatory limit of 1000 µg/kg (1.0 mg/kg) with direct sample-to-cassette application (eliminating separate microwell incubation), this kit delivers clear visual results in just 5 to 8 minutes for grain silos, flour mills, feed manufacturers, and food safety inspection labs.
Regulatory MRL Precision (1000 µg/kg LOD): Calibrated directly to the 1000 µg/kg (1.0 ppm) statutory maximum residue threshold for cereal grains and grain-based ingredients.
Streamlined Direct-Load Format: Requires no pre-incubation in separate microwells—simply dispense 100 µL of diluted sample extract directly into the cassette sample well.
Fast 5–8 Minute Visual Readout: Generates crisp, unambiguous competitive lateral flow lines within 5 to 8 minutes, accelerating truckload intake and milling release.
Calibrated Grain & Legume Dilution Guide: Provides dedicated dilution ratios tailored for both cereal grains (corn, wheat, rice, oats) and legumes/oilseeds (soybeans, peanuts, mung beans, red beans).
Extended 18-Month Ambient Shelf Life: Stored tightly sealed at 4–30°C in a cool, dry place for up to 18 months without cold-chain refrigeration overhead.
| Product Name | Vomitoxin (DON) Rapid Test Kit |
|---|---|
| Catalog Number | 12103 |
| Target Mycotoxin | Vomitoxin / Deoxynivalenol (DON) |
| Detection Principle | Competitive Lateral Flow Immunochromatography (Direct-Load Colloidal Gold) |
| Limit of Detection (LOD) | 1000 µg/kg (1.0 mg/kg) |
| Pack Size & Sample Volume | 10 tests / kit; 100 µL diluted sample solution directly into cassette well |
| Visual Reading Window | 5 – 8 minutes (Results invalid after 10 minutes) |
| Storage & Shelf Life | 18 months sealed at 4–30°C in a cool, dry place (Do not freeze) |
| Sample Matrix Classification | Supernatant | Sample Diluent | Targeted LOD |
|---|---|---|---|
| Cereal Grains (Corn, Wheat, Rice, Oats, Black Rice, Brown Rice, Glutinous Rice) | 50 µL | 1000 µL | 1000 µg/kg |
| Legumes & Oilseeds (Soybeans, Peanuts, Mung Beans, Red Beans) | 50 µL | 600 µL | 1000 µg/kg |
Validated for rapid qualitative screening of Vomitoxin (DON) across staple grains and pulses:
STEP 1 Extraction Grind representative grain sample. Weigh 1.00 ± 0.05 g into a 10 mL tube, add 5 mL Extraction Solution, vortex 3 min, and centrifuge at 4000 rpm for 3 min. | STEP 2 Matrix Dilution Pipette 50 µL supernatant into a 2 mL tube. Add 1000 µL Sample Diluent (for cereals) or 600 µL Diluent (for beans/peanuts), and shake well to mix. | STEP 3 Direct Cassette Load Equilibrate cassette and solution to 20–40°C. Place cassette flat and dispense 100 µL of diluted sample solution directly into the sample well. Start timing. | STEP 4 Read at 5–8 Mins Interpret visual lines strictly between 5 and 8 minutes post-loading. Visual readouts become invalid after 10 minutes due to late chemical shifts. |
Negative (-): Both Control (C) line and Test (T) line appear clearly (T line color intensity equal to or darker than C line) → Vomitoxin (DON) is absent or below the 1000 µg/kg LOD threshold.
Positive (+): Control (C) line appears distinctly, while Test (T) line is visibly weaker/lighter than C line or invisible → Vomitoxin concentration meets or exceeds 1000 µg/kg. Confirm positive samples via HPLC or LC-MS/MS.
Invalid: Control (C) line fails to appear, regardless of whether T line is visible. Re-test using a new cassette.
Adhere to strict operational parameters to ensure maximum screening accuracy:
Moisture Protection: To prevent atmospheric humidity from degrading the test strip membrane, begin testing within 1 hour after removing the cassette from its sealed foil pouch.
Pouch Integrity Inspection: Check the aluminum foil pouch before testing; do not use any test cassette if the protective pouch is damaged or punctured.
Strict Time Window: Read visual test results strictly between 5 and 8 minutes post-loading; results observed after 10 minutes are invalid.
Temperature Equilibration: Ensure both the test cassette and prepared sample solution are equilibrated to 20–40°C prior to dispensing onto the cassette.
Kit Components Included (10 Tests): 10 Test cassettes (individually sealed), Extraction solution (60 mL) ×1, Sample diluent (15 mL) ×1, 2 mL Centrifuge tubes ×10, 10 mL Centrifuge tubes ×10, User Manual.
Required Equipment (Not Provided): Grain grinder/mill, precision balance (±0.05 g), vortex mixer, micropipettes (50 µL, 100 µL, 1000 µL) & tips, centrifuge (≥ 4000 rpm), and timer.