8–10 mins Rapid Readout Time | 5 mg/kg Strict Target LOD | 10 Tests Complete Kit Pack | 12 Months Shelf Life (4–30°C) |
The FSTest Organochlorines Rapid Test Kit is a professional-grade rapid screening tool engineered for the qualitative detection of organochlorine pesticide residues in fresh fruits and vegetables.
Organochlorines, including Endosulfan, Dieldrin, and Hexachlorocyclohexane (HCH), are highly persistent environmental pollutants heavily regulated in global agricultural trade. By eliminating the immediate necessity for complex laboratory equipment (such as HPLC or GC-MS), this field-ready assay compresses chemical extraction into a simplified room-temperature workflow, delivering reliable visual results within 8 to 10 minutes.
High-Speed Field Turnaround: Complete the entire screening assay workflow and read stable visual results within 8 to 10 minutes post-sample-preparation.
Target Multi-Analyte Detection: Calibrated to yield dependable qualitative screenings for major organochlorine compounds (Endosulfan, Dieldrin, Hexachlorocyclohexane) at 5 mg/kg.
High Specificity & Zero Cross-Reactivity: Proven unaffected by non-target agrochemicals up to 1 mg/L (including Thiamethoxam, Triazophos, Parathion, Carbofuran, and Omethoate).
Safe & Operator-Friendly Formulation: The specialized extraction solution supplied in the kit is certified as safe and non-toxic for operators, allowing standard chemical waste disposal.
Convenient Room Temp Storage: Offers a full 12-month shelf life when sealed and stored at 4–30°C in a cool, dry location.
| Product Name | Organochlorines Rapid Test Kit (Colloidal Gold) |
|---|---|
| Detection Principle | Competitive Lateral Flow Immunochromatography |
| Pack Size | 10 tests / kit |
| Assay Run Time & Volume | 8–10 minutes (results invalid after 10 minutes); 100 µL test solution |
| Storage & Shelf Life | 12 months sealed at 4–30°C in a cool, dry place (Do not freeze) |
| Active Target Compound | CAS Registry Number | Molecular Formula & Weight | LOD Threshold |
|---|---|---|---|
| Endosulfan | 115-29-7 | C₉H₆Cl₆O₃S (406.925 g/mol) | 5 mg/kg |
| Dieldrin | 60-57-1 | C₁₂H₈Cl₆O (380.91 g/mol) | 5 mg/kg |
| Hexachlorocyclohexane (HCH) | 6108-10-7 | C₆H₆Cl₆ (290.83 g/mol) | 5 mg/kg |
Validated for multi-matrix organochlorine screening across agricultural fresh produce:
STEP 1 Comminution Cut the fresh fruit or vegetable sample into small pieces (approx. 0.5 cm × 0.5 cm). Weigh exactly 2.0 ± 0.1 g into a 30 mL sampling bottle. | STEP 2 Extraction Add 5 mL of extracting solution, shake/vortex thoroughly for 2 minutes, and let stand for 1 minute to settle. (Centrifuge at 4000 rpm for 3 min if cloudy). | STEP 3 Load Cassette Ensure 20–40°C cassette environment. Pipette 100 µL of prepared clear sample solution directly into the sample well of the cassette. Start timing. | STEP 4 Read at 8–10 Mins Interpret visual lines strictly at 8–10 minutes. Visual readouts become strictly invalid after 10 minutes due to late chemical shifts. |
Negative (-): Both Control (C) line and Test (T) line develop a strong, distinct red band. Targeted organochlorine residues are safely below 5 mg/kg.
Positive (+): Control (C) line develops normally, but Test (T) line is visibly lighter or fails to appear → Organochlorines residue ≥ 5 mg/kg threshold limit.
Invalid: Control (C) line fails to show any visible color band. Re-testing with a new cassette is required.
Adhere to strict operational parameters to ensure maximum screening accuracy:
Qualitative Screening Purpose: Engineered strictly for qualitative preliminary screening; not intended for precise quantitative concentration evaluation.
Time-Sensitive Exposure: Perform assay within 1 hour after removing cassette from foil pouch to prevent ambient moisture damage.
Environmental Thresholds: Maintain operating temperature between 5–40°C and relative humidity at 30%–80%, sheltered from wind.
Kit Components Included: 10 Test cassettes, Extracting solution (50 mL) x1, 30 mL Sampling bottles (x2), User Manual.
Required Equipment (Not Provided): Scissors, electronic balance (2.0 ± 0.1 g precision), micropipette (100 µL), centrifuge (optional, for turbid extracts), and timer.