8–10 mins Rapid Readout Time | 0.1–5 mg/kg Tunable Matrix LOD | 10 Tests Complete Kit Pack | 12 Months Shelf Life (4–30°C) |
The FSTest Imidacloprid Rapid Test Kit is a professional-grade rapid screening tool engineered for the qualitative detection of imidacloprid residues in fresh fruits, vegetables, and leafy greens.
Imidacloprid is a widely utilized neonicotinoid insecticide. By bypassing the need for complex, time-consuming laboratory infrastructure (such as HPLC or GC-MS), this field-ready kit compresses complex agricultural sample extraction into a simplified room-temperature workflow, delivering reliable visual results within 8 to 10 minutes for fresh produce supply chains and corporate food safety compliance monitoring programs.
Ultra-Fast Field Turnaround: Complete the entire assay workflow and achieve highly reliable visual result readouts within 8 to 10 minutes post-sample-preparation.
Highly Customizable Limits of Detection: Uniquely calibrated to adapt across different produce matrices, targeting regulatory cut-off thresholds ranging from 0.1 mg/kg up to 5 mg/kg via standard or 2-step serial dilution protocols.
Fully Self-Contained Kit Architecture: Packed with all required consumables—including 10 test cassettes, 20 centrifuge tubes (2 mL), 100 mL extracting solution, and 2 sampling bottles (30 mL).
Definite Visual Interpretation: Utilizes a competitive lateral flow format where an increasing insecticide concentration causes the Test (T) line to fade or disappear, removing subjective reading errors.
Ambient Transport & Easy Storage: Sealed kits can be safely kept in a cool, dry location between 4–30°C for up to 12 months.
| Product Name | Imidacloprid Rapid Test Kit (Colloidal Gold) |
|---|---|
| Target Analyte Compound | Imidacloprid (CAS: 138261-41-3 / 105827-78-9) |
| Detection Principle | Competitive Inhibition Lateral Flow Immunochromatography |
| Pack Size | 10 tests / kit |
| Assay Run Time & Volume | 8–10 minutes (results invalid after 10 minutes); 100 µL final prepared solution |
| Storage & Shelf Life | 12 months sealed at 4–30°C in a cool, dry place (Do not freeze) |
| Applicable Fruit & Vegetable Commodity | Target LOD (mg/kg) | Supernatant X (µL) | Diluent Y (µL) |
|---|---|---|---|
| Garlic, onion, balsam pear, wax gourd, pumpkin, kidney bean, vegetable soybean, sweet potato, bamboo shoots | 0.1 mg/kg | 100 µL | 300 µL |
| Sweet potato leaves, Chinese cabbage, pepper, asparagus, carrots | 0.2 mg/kg | 100 µL | 700 µL |
| Garlic scape, Brussels sprouts, cabbage, chieh-qua, silk melon, broad bean, pea, rhizome vegetables (except carrot), potatoes, Zizania | 0.5 mg/kg | 950 µL | 50 µL |
| Chinese chive, cabbage, cauliflower, broccoli, Chinese kale, lettuce, eggplant, pepper, cucumber, zucchini | 1.0 mg/kg | 780 µL | 20 µL |
| Common cowpea | 2.0 mg/kg | 790 µL | 10 µL |
| Applicable High LOD Commodity | Target LOD (mg/kg) | Sequential Two-Step Dilution Protocol |
|---|---|---|
| Spinach, kales | 5.0 mg/kg | Step 1: Pipette 100 µL primary supernatant + 900 µL extracting solution, swirl 30 s. Step 2: Pipette 50 µL solution from Step 1 + 950 µL extracting solution, swirl 30 s for final test. |
Extensively validated across diverse agricultural produce matrices:
STEP 1 Comminution Cut fresh sample into 0.5 cm pieces. Weigh 1.0 ± 0.1 g into 30 mL sampling bottle, add 5 mL extracting solution, shake 1 min, let stand 1 min. | STEP 2 Matrix Dilution Execute the specific Standard or Two-Step Serial Dilution protocol as defined in the tables above based on the produce type being tested. | STEP 3 Load Cassette Ensure 20–60°C environment. Pipette 100 µL of final prepared matrix-diluted solution into round sample well on cassette. Start timing. | STEP 4 Read at 8–10 Mins Interpret visual lines strictly at 8–10 minutes. Visual readouts become strictly invalid after 10 minutes due to late chemical shifts. |
Negative (-): Both Control (C) line and Test (T) line develop strong, distinct red bands. Imidacloprid residue is safely below the targeted matrix LOD limit.
Positive (+): Control (C) line develops normally, but Test (T) line is visibly lighter or fails to appear → Imidacloprid residue ≥ targeted matrix LOD limit.
Invalid: Control (C) line fails to show any visible color band. Re-testing with a new cassette is required.
Adhere to strict operational parameters to ensure maximum screening accuracy:
Qualitative Screening Purpose: Engineered strictly for qualitative preliminary screening; not intended for precise quantitative concentration evaluation.
Dilution Protocol Accuracy: Ensure exact execution of Standard Protocol vs. Two-Step Serial Protocol based on matrix type to match target regulatory LOD cutoffs.
Time-Sensitive Exposure: Perform test within 1 hour after removing cassette from pouch. Read visual results strictly between 8–10 minutes.
Kit Components Included: 10 Test cassettes, 2 mL Centrifuge tubes (x20), Extracting solution (100 mL) x1, 30 mL Sampling bottles (x2), User Manual.
Required Equipment (Not Provided): Scissors, electronic balance (1.0 ± 0.1 g precision), micropipettes (X & Y µL, 100 µL), vortexer, centrifuge (optional, for turbid extracts), and timer.