10–12 mins Rapid Readout Time | 0.2 mg/kg Strict DDT LOD | 10 Tests Complete Kit Pack | 12 Months Shelf Life (4–30°C) |
The FSTest DDT Rapid Test Kit is a professional-grade, rapid screening tool engineered for the qualitative detection of DDT (dichlorodiphenyltrichloroethane) residues in fresh fruits and vegetables.
DDT is a highly regulated, persistent organochlorine pesticide. By bypassing the need for complex, time-consuming laboratory chromatography infrastructure (such as GC-MS), this field-ready kit compresses agricultural sample extraction into a simplified room-temperature workflow, serving as an indispensable first-line defense in fresh produce supply chains and corporate food safety compliance monitoring programs in just 10 to 12 minutes.
Rapid Field Turnaround: Complete the entire assay workflow and achieve highly reliable visual result readouts within just 10 to 12 minutes post-preparation.
Highly Sensitive Baseline Detection: Calibrated to yield dependable qualitative screenings at a strict Limit of Detection (LOD) of 0.2 mg/kg (ppm) across fresh produce matrices.
Fully Self-Contained Kit Architecture: Arrives fully packed with 10 test cassettes, 10 microwells, 1 bottle of extracting solution (50 mL), and 10 sampling bottles (30 mL).
High Specificity & Zero Cross-Reactivity: Rigorously validated to show zero cross-reactivity with non-target agrochemicals up to 1 mg/L (including Thiamethoxam, Triazophos, Parathion, Carbofuran, and Omethoate).
Safe & Non-Toxic Formulation: Supplied with an officially certified safe and non-toxic specialized extraction solution for hassle-free processing on-site.
| Product Name | DDT Rapid Test Kit (Colloidal Gold) |
|---|---|
| Target Analyte Compound | DDT (2,2-bis-(p-Chlorophenyl)-1,1,1-trichloroethane) (CAS: 50-29-3) |
| Detection Principle | Competitive Inhibition Lateral Flow Immunochromatography |
| Pack Size | 10 tests / kit |
| Assay Run Time & Volume | 10–12 minutes (results invalid after 12 minutes); 120 µL mixed test solution |
| Storage & Shelf Life | 12 months sealed at 4–30°C in a cool, dry place (Do not freeze) |
| Target Analyte Compound | CAS Registry Number | LOD Threshold |
|---|---|---|
| DDT (2,2-bis-(p-Chlorophenyl)-1,1,1-trichloroethane) | 50-29-3 | 0.2 mg/kg (ppm) |
Validated for multi-matrix organochlorine screening across fresh agricultural produce:
STEP 1 Extraction Cut fresh sample into 0.5 cm pieces. Weigh 2.0 ± 0.1 g into 30 mL sampling bottle, add 3 mL extracting solution, vortex 2 min, let stand 1 min. | STEP 2 Microwell Step Ensure 20–40°C environment. Pipette 120 µL clear supernatant into microwell, mix gently 3–5 times, and let stand undisturbed for 3 min. | STEP 3 Load Cassette Transfer 120 µL of mixed solution from microwell directly into round sample hole on cassette. Start timing immediately for lateral flow migration. | STEP 4 Read at 10–12 Mins Interpret visual lines strictly at 10–12 minutes. Visual readouts become strictly invalid after 12 minutes due to late chemical shifts. |
Negative (-): Both Control (C) line and Test (T) line develop strong, distinct red bands. DDT residue is safely below 0.2 mg/kg.
Positive (+): Control (C) line develops normally, but Test (T) line is visibly lighter or fails to appear → DDT residue ≥ 0.2 mg/kg threshold limit.
Invalid: Control (C) line fails to show any visible color band. Re-testing with a new cassette is required.
Adhere to strict operational parameters to ensure maximum screening accuracy:
Qualitative Screening Purpose: Engineered strictly for qualitative preliminary screening; not intended for precise quantitative concentration evaluation.
Time-Sensitive Exposure: Perform test within 1 hour after removing cassette from protective foil pouch to avoid ambient moisture damage.
Strict Time Window: Read visual test results strictly between 10–12 minutes after loading cassette; results observed after 12 minutes are invalid.
Kit Components Included: 10 Test cassettes, 10 Microwells, Extracting solution (50 mL) x1, 30 mL Sampling bottles (x10), User Manual.
Required Equipment (Not Provided): Scissors, electronic balance (2.0 ± 0.1 g precision), micropipette (120 µL), vortexer, and timer.