home_icon
Home
>
Products
>
Dairy and Water Series
>
β-Lactams + Tetracyclines + Streptomycins + CAP (BTSC) Rapid Test Strip
β-Lactams + Tetracyclines + Streptomycins + CAP (BTSC) Rapid Test Strip
Brand: FSTest
CatNO: 11107
Specifications: 96 tests/kit
Shelf life: 18 months
Application: Designed to simultaneously screen for β-Lactams, Tetracyclines, Streptomycins, and CAP residues in raw milk, pasteurized milk,milk powder,goat's milk, camel's milk, and buffalo milk.
β-Lactams + Tetracyclines + Streptomycins + CAP (BTSC) Rapid Test Strip
β-Lactams + Tetracyclines + Streptomycins + CAP (BTSC) Rapid Test Strip
β-Lactams + Tetracyclines + Streptomycins + CAP (BTSC) Rapid Test Strip
β-Lactams + Tetracyclines + Streptomycins + CAP (BTSC) Rapid Test Strip

β-Lactams + Tetracyclines + Streptomycins + Chloramphenicol (CAP) 4-in-1 Rapid Test Strip

Industrial Multiplex Screening Tool for Dairy Antibiotic Residue Compliance
4-IN-1 MULTIPLEX TEST
       Cat NO.: 11107 | Brand: FSTest
7 mins
Rapid Readout Time
0.3 µg/kg
Ultra-Strict CAP LOD
96 Tests
Commercial Bulk Pack
30 Days
Ambient Transport Allowed
1. Product Overview

The FSTest β-Lactams + Tetracyclines + Streptomycins + Chloramphenicol (CAP) 4-in-1 Rapid Test Strip (CatNO: 11107) is a professional-grade, industrial multiplex screening tool engineered for the simultaneous, independent detection of four major high-risk veterinary drug residue categories in dairy products.

Antibiotic and antimicrobial residues in dairy production present critical food safety challenges and are subject to strict Maximum Residue Limits (MRLs) or absolute zero-tolerance prohibitions worldwide. By consolidating four distinct veterinary drug screenings into a single, straightforward assay loop, this kit eliminates the necessity for complex multiple extraction protocols or separate ELISA microplate platforms. It compresses essential multi-residue milk verification into a simplified, field-ready ambient workflow for dairy farms, collection stations, pasteurization plants, and QA laboratories.

2. Key Benefits
  • High-Speed Quad-Multiplex Screening: Maps out a comprehensive safety profile spanning four major contaminant groups in a single test sequence with visual results in just 7 minutes.

  • Ultra-High Sensitivity Thresholds: Calibrated to meet or surpass global regulatory cutoffs, including Chloramphenicol down to 0.3 µg/kg, Streptomycins down to 50 µg/kg, Tetracyclines down to 5 µg/kg, and Beta-Lactams down to 1–2 µg/kg.

  • Extensive Dairy Matrix Adaptability: Formulated for multi-matrix sample validation, offering reliable screening across raw milk, pasteurized liquid milk, and reconstituted milk powder.

  • Zero-Ambiguity Visual Layout: Features four separate invisible Test lines (T1, T2, T3, T4) paired with an integrated internal Control (C) line for clear reading without cross-line interference.

  • Heavy-Duty Commercial Specification: Supplied in a bulk 96-test pack (96 test strips and 96 dry-reagent precoated microwells) optimized for high-throughput batch auditing.

  • Flexible Shelf Life & Transport: Offers an 18-month refrigerated lifespan (2–8°C) with an advanced ambient tolerance profile permitting room-temperature transport and field deployment for up to 30 days.

3. Technical Specifications & LOD Spectrum
Product Nameβ-Lactams + Tetracyclines + Streptomycins + CAP 4-in-1 Rapid Test Strip
Catalog Number (CatNO)11107
Assay MechanismCompetitive Multiplex Lateral Flow Immunochromatography
Pack Size96 Tests / Kit (96 Test Strips + 96 Precoated Microwells)
Test Time3 minutes microwell incubation + 7 minutes strip reaction
Storage & Shelf Life18 months at 2–8°C; allows up to 30 days ambient transport/storage at room temp
Detailed Analyte Sensitivity Spectrum (Limit of Detection / LOD)
Target Group (Test Line)Target Analyte CompoundCAS NumberFormula / Mol. WeightLOD Cutoff
1. Chloramphenicol (T1 Line)Chloramphenicol (CAP)56-75-7C₁₁H₁₂Cl₂N₂O₅ (323.13 g/mol)0.3 µg/kg
2. Streptomycins (T2 Line)Streptomycin sulfate3810-74-0C₂₁H₄₂N₇O₁₈ (728.69 g/mol)50 µg/kg
Dihydrostreptomycin5490-27-7C₂₁H₄₁N₇O₁₂ (730.71 g/mol)50 µg/kg
3. Tetracyclines (T3 Line)Tetracycline60-54-8C₂₂H₂₄N₂O₈ (444.44 g/mol)5 µg/kg
Chlortetracycline57-62-5C₂₂H₂₃ClN₂O₈ (478.88 g/mol)5 µg/kg
Oxytetracycline79-57-2C₂₂H₂₄N₂O₉ (460.43 g/mol)5 µg/kg
Doxycycline100929-47-3C₂₂H₂₅ClN₂O₈ (480.89 g/mol)5 µg/kg
4. Beta-Lactams (T4 Line) CompoundCAS Registry NumberLOD Threshold (µg/kg)
Penicillin G Sodium69-57-81–2 µg/kg
Penicillin-V87-08-12–4 µg/kg
Piperacillin61477-96-12–4 µg/kg
Ampicillin Trihydrate7177-48-22–4 µg/kg
Amoxicillin61336-70-72–4 µg/kg
Oxacillin66-79-52–4 µg/kg
Cloxacillin61-72-32–4 µg/kg
Cefoperazone62893-19-02–4 µg/kg
Cephalonium5575-21-32–4 µg/kg
Cefacetrile10206-21-08 µg/kg
Nafcillin147-52-410 µg/kg
Cefapirin21593-23-710 µg/kg
Cephalothin153-61-710 µg/kg
Cefquinome sulfate118443-89-320 µg/kg
Ceftiofur80370-57-650 µg/kg
Ceftriaxone73384-59-5100 µg/kg
Cefazolin25953-19-9100 µg/kg
Cefalexin23325-78-21000 µg/kg
4. Applicable Sample Types

Extensively validated for multi-matrix dairy applications across the supply chain:

Raw Liquid Bovine Cow Milk    Pasteurized & UHT Commercial Liquid Milk    Reconstituted Milk Powder (1:9 water ratio)    Dairy Farm Bulk Tanks & Tanker Trucks
5. Test Procedure
STEP 1
Sample Prep
Equilibrate milk to 20–40°C. For powder, mix 1 g powder in 9 mL distilled water. Take out strips/wells and re-cap container immediately.
STEP 2
Mix & Incubate
Pipette 150 µL milk into precoated microwell. Mix thoroughly by repeated pipetting and incubate for 3 min (at room temp or 40°C if ambient < 20°C).
STEP 3
Insert Strip
Insert test strip with sample end down into microwell. Start timing immediately for lateral flow reaction.
STEP 4
Read at 7 Mins
Read visual lines strictly at 7 minutes. Results become invalid after 10 minutes due to post-reaction chemical shifts.
Visual Results Determination Guide:
  • Negative (-): Control (C) and all four Test lines (T1, T2, T3, T4) show strong, distinct red bands matching or darker than C-line. (All 4 groups below cutoff).

  • T1 Positive (+): T1 line is visibly lighter than C-line or disappears completely, Chloramphenicol(CAP) residue  0.3 µg/kg.

  • T2 Positive (+): T2 line is visibly lighter than C-line or disappears, Streptomycins residue ≥ 50 µg/kg.

  • T3 Positive (+): T3 line is visibly lighter than C-line or disappears, Tetracyclines residue  5 µg/kg.

  • T4 Positive (+): T4 line is visibly lighter than C-line or disappears, Beta-Lactams residue   threshold limit.

  • Multiplex Positive (+): Multiple faded or absent T-lines indicate co-existing multi-drug contamination.

  • Invalid: Control (C) line fails to develop a visible color band. Re-testing with a new strip is required.

6. Performance & Crucial Handling Controls

Adhere to strict operational parameters to ensure maximum screening accuracy:

  • Qualitative Screening Purpose: Engineered strictly for rapid qualitative prescreening and preliminary field audits. Confirmatory laboratory testing is recommended if necessary.

  • Air Exposure Window: Perform test within 30 minutes after pulling strips from vial to prevent dampness and loss of reactivity.

  • Meticulous Pipetting: Thoroughly resuspend dry microwell reagents via repeated fluidic pipetting; improper mixing impairs line development.

  • Environmental Limits: Maintain operating relative humidity at 30%–80%. Avoid wind currents and testing above 40°C. Do not touch white membrane area.

7. Compatible Field Accessories
  • Dairy Portable Incubator Block (40°C): Constant temperature incubator block for standardized testing when ambient temperature is below 20°C.

Request Samples & Ordering Information
Evaluate the FSTest β-Lactams + Tetracyclines + Streptomycins + CAP 4-in-1 Rapid Test Strip (CatNO: 11107) in your dairy quality control workflows. Free evaluation sample packs are available for certified testing laboratories and dairy producers.

     Email: service@fstestcorp.com | Website: www.fstestcorp.com
     Manufacturer: FSTest Co., Ltd.
Certification & Validation
scroll_top_icon
A-
A+
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish.